← Gallery

50 hp Motor Cutaway: Power Flow and Losses

A cutaway of a 50 hp, 460 V motor showing 40.11 kW of electrical input and 37.3 kW of shaft output (93.0% efficiency), with each loss labeled (stator copper, rotor copper, core, friction, windage and stray load) and a power flow summary table.