Diagnose
Engineering Troubleshooting Guides
Start from the symptom. Each guide lists the likely causes with what to check for each, a small worked calculation, and how to write a problem statement another engineer can act on.
See the guidesElectrical & Power
Why Is an Electric Motor Overheating?
The common causes of motor overheating (overload, voltage problems, poor cooling, duty, drives and bearings), what to check for each, and a worked loss calculation.
Why Does a Circuit Breaker Keep Tripping?
Overload, short circuit, ground fault, inrush, loose connections and heat: how to tell the causes apart from how and when the breaker trips.
Why Does a VFD Trip on Overcurrent or Overvoltage?
The common causes of variable frequency drive overcurrent, overvoltage and overload faults, what points to each, and what to check.
Why Is a Transformer Humming Loudly or Running Hot?
Normal hum versus abnormal noise, and the common causes of transformer overheating: overload, harmonics, poor ventilation, loose connections and voltage problems.
Why Does a GFCI Keep Tripping?
Ground-fault current, moisture, shared neutrals, damaged appliances and nuisance trips: how to tell the causes apart.
Why Do My Lights Flicker or Dim When Equipment Starts?
Starting current causes a voltage dip across the supply impedance. Covers motors, loose connections, weak supply and LED drivers.
Why Is an Outlet Not Working When the Breaker Hasnβt Tripped?
A dead outlet with the breaker on usually means an upstream GFCI, a switched outlet, a broken supply path or a bad connection. How to narrow it down.
Why Is My UPS Beeping or Showing Replace Battery?
UPS beeps and Replace Battery lights mean battery operation, overload, a worn battery or a fault. Includes a load-versus-runtime example.
Why Wonβt My Electric Motor Start, or Why Does It Only Hum?
A motor that only hums is trying to start and cannot. Separates the start command, supply, start components, load and motor, single and three-phase.
Why Are My Three-Phase Motor Currents Unequal?
Unequal motor currents come from voltage unbalance, connections or motor faults. Includes the percentage-unbalance calculation.
Why Does a Contactor Chatter or Drop Out?
A contactor chatters when the coil lacks steady voltage. Covers control-voltage dips, coil rating, intermittent commands and wear.
Why Does My VFD Trip on Undervoltage?
A drive trips on undervoltage when its DC bus falls below the limit. Covers supply dips, other starts, connections and fault-history timing.
Mechanical, HVAC & Fluids
Why Is a Pump Delivering Low Flow or Making Noise?
Cavitation, air in the line, a blocked suction, a worn impeller, wrong rotation and system changes: how to separate the causes from the symptoms.
Why Is an Air Conditioner Not Cooling Enough?
Airflow, refrigerant charge, dirty coils, controls and electrical faults: how to separate the common causes of poor cooling, with the temperature-split check.
Why Is My AC Freezing Up?
Low airflow, a dirty coil, low refrigerant and operating conditions can all ice an AC coil. Ice alone does not name the cause. How to tell them apart.
Why Is My Air Conditioner Leaking Water Indoors?
Indoor AC water usually comes from a blocked drain, a full pan, a failed condensate pump or thawing ice. How to separate drainage from cooling faults.
Why Does My AC Keep Turning On and Off?
Short cycling comes from controls, airflow limits, oversizing and protective shutdowns. Includes a cycle-timing example of an oversized unit.
Why Is My Furnace Running but Not Heating?
A furnace blower can run with no heat being made. Separate blower operation from the ignition sequence, airflow limits and fault codes.
Why Is My Heat Pump Running but Not Heating Enough?
Operating mode, defrost, cold weather, airflow and backup heat limit heat pump output. Includes a balance-point example.
Why Does My Air Compressor Run Continuously or Build Pressure Slowly?
Demand, leaks, inlet restrictions, controls and wear keep a compressor running. Includes a supply-versus-demand balance and a leak test.
Why Is Chilled-Water Delta-T Too Low?
Low delta-T means water returns too cold for the heat it carries. Causes: flow, load, bypass, coil performance and sensor accuracy.
Why Is One Room Too Hot While Others Are Comfortable?
Air distribution, zoning, local loads, schedules and sensor location explain a single hot room. Includes an airflow-versus-load check.
Why Is My AHU Airflow Low Despite High Fan Speed?
Filters, dampers, duct restrictions, fan condition and measurement errors cause low AHU airflow at full speed. Includes a duct traverse example.
Controls & Instrumentation
Why Is a 4-20 mA Loop Reading Wrong or Stuck?
Open circuits, ground loops, insufficient supply voltage, wrong range and failed transmitters: a step-by-step way to isolate a faulty 4-20 mA loop.
Why Does a PLC Output Not Turn On the Field Device?
Logic, forced values, output module faults, blown output fuses, missing field power and wiring: a systematic way to find where the signal stops.
Why Does My PLC Lose Communication with Modbus Devices?
Modbus RTU and TCP fail in different ways. Covers addressing, serial settings, wiring, termination, network setup and timeouts, with a polling example.
Why Are My Modbus Values Wrong Even Though Communication Works?
When replies arrive but numbers are wrong, check register offsets, data types, word order, signed values and scaling, with a decoded register.
Why Does My PID Loop Keep Oscillating?
Tuning, process delay, valve behavior, noise and disturbances make a PID loop cycle. How the trends tell the causes apart.
Why Does My Control Valve Hunt or Stick?
Stiction, deadband, positioner behavior, air supply and oversizing cause valve hunting. Compare commanded and actual position.
Why Is My Temperature Sensor Reading Incorrectly?
RTD versus thermocouple setup, wiring, compensation, placement and scaling explain wrong readings. Includes 2-wire RTD lead error.
Fire Protection
Why Does the Fire Alarm Panel Show a Ground Fault Trouble?
What a ground fault trouble means, where the leakage usually comes from, and how to isolate it by circuit without taking the whole system off line.
Why Does the Fire Alarm Panel Show Battery Trouble?
Fire alarm battery trouble comes from battery condition, charging, connections and temperature. Why a battery can pass a voltage check and fail.
Why Does the Fire Alarm Panel Show an Open-Circuit or NAC Trouble?
A supervised NAC reports trouble for a break, missing end-of-line device, incompatible device or configuration error. What the panel measures.
Why Does a Sprinkler System Have Repeated Low-Air Supervisory Signals?
Low-air signals on dry sprinkler systems come from leaks, air supply, pressure controls and temperature. Includes a gas-law example.
How these pages work
Describe the symptom
Record what happened, when, and what changed.
List the causes
Each guide ranks the usual causes and what points to them.
Check, then fix
Measurements by qualified people, following site safety rules.
Write it down
Separate what you observed from what you concluded.
Questions
Can I use these guides to work on live equipment?
They are learning material. Electrical measurements and repairs belong with qualified personnel following lockout/tagout and the site safety procedures.
Do the guides replace the manufacturer manual?
No. Limits such as temperature class and rated voltage come from the nameplate and manufacturer documents.
Educational material. Examples use simplified, hypothetical inputs and are not a design, a construction document or professional engineering advice. Confirm requirements with the codes and standards adopted where the work is built and with a licensed engineer.
More: Worked Problems Β· Comparisons Β· Case Studies Β· Exam Study Plans Β· First 90 Days