START WITH THE FOUNDATIONS

Robotics & Automation Foundations

Connect coordinates, motion timing and feedback in a simplified robot task.

Free · No sign-in required3 lessonsWorked examples & practiceBeginner

0 of 3 lessons checked · Progress is saved in this browser.

  1. 01 / SYSTEM VIEWTask coordinates
  2. 02 / SYSTEM VIEWMotion command
  3. 03 / SYSTEM VIEWPosition feedback

This map connects the course ideas; it is not a detailed engineering schematic.

LESSON 1 / 3 · FREE

Coordinate frames

Your goal: State the reference frame for every position.

Understand the idea

A robot’s point coordinates depend on the selected frame. Tool, base and workpiece frames serve different roles. Translating a coordinate frame is simpler than a general rotation; this introductory example deliberately uses a one-dimensional translation only.

Worked example

A tool point at 100 mm in a local frame with origin 200 mm along the base axis has base position 300 mm, with aligned axes.

Try it yourself

With aligned axes, add a 150 mm local coordinate to a 250 mm frame offset.

Can coordinates be combined without knowing their frames?

Background reference ↗ · Original teaching text and fictional practice values.

Continue to lesson 2: Speed and travel time →

LESSON 2 / 3 · FREE

Speed and travel time

Your goal: Separate a constant-speed estimate from a real motion profile.

Understand the idea

Distance divided by speed gives travel time only for the assumed constant-speed segment. Real motion includes acceleration, deceleration, path constraints and dwell. An arithmetic estimate is not a robot cycle-time guarantee or an authorization to move equipment.

Worked example

At an assumed constant 0.5 m/s, a 2 m segment takes 4 s, excluding acceleration and stops.

Try it yourself

At constant 0.4 m/s, calculate time for 1.2 m.

What is omitted by a constant-speed time estimate?

Background reference ↗ · Original teaching text and fictional practice values.

Continue to lesson 3: Feedback error →

LESSON 3 / 3 · FREE

Feedback error

Your goal: Compare a commanded and measured position with a defined sign convention.

Understand the idea

Closed-loop motion compares feedback with a target and updates actuator commands. Here error is target minus measured position. Sensor resolution, calibration, backlash and dynamics affect performance. A zero displayed error is not proof of safe separation or validated machine safety.

Worked example

A target of 100 mm and measured 98 mm produce +2 mm error under the stated convention.

Try it yourself

For target 250 mm and measured 246 mm, find signed error.

Does zero reported position error establish machine safety?

Background reference ↗ · Original teaching text and fictional practice values.

Choose your next step →

Finish with evidence of your understanding.

Explain each worked example in your own words, check the units and identify one assumption that could change the result. Then use the linked labs or roadmap to apply the ideas to a broader task.

Practice progress is a study aid, not a professional qualification or proof of field competence.

Continue in Robotics & Automation

Apply these foundations in an available course, lab or roadmap. The linked resource’s access rules still apply.

Show 18 more available resources

Open the full studio → · Choose another discipline →

About this introductory course

These original lessons use simplified models and explicitly supplied practice values. Calculations teach concepts; they do not select real equipment, establish code compliance or authorize field work. Follow the linked references and advanced resources for deeper study.

Updated · Study progress stays in this browser. There is no certificate or paid gate for these lessons.