Concentrate a 5,000 kg/h feed from 10% to 35% solids and find the product flow, water evaporated, heat duty, steam use and steam economy.
Chemical & Process · Last reviewed
Given
A single-effect evaporator concentrates 5,000 kg/h of feed from 10% to 35% nonvolatile solids by mass. The feed enters at 30 °C and the liquid boils at 100 °C (neglect boiling-point rise). Supplied thermal data for the exercise: feed heat capacity 3.8 kJ/kg·K, latent heat of water at 100 °C 2,257 kJ/kg, and latent heat of the heating steam 2,174 kJ/kg.
Find
The product flow, the water evaporated, the heat duty, the steam flow and the steam economy.
Solution
Related tools and labs
Calculators, labs and simulators are part of the All-Access Pass.
More worked problems
- CSTR vs PFR: Conversion for a First-Order Reaction
- Mixing Two Solutions: Flow and Concentration
- Arrhenius Equation: How Temperature Changes Reaction Rate
- Recycle and Purge: Preventing Inert Buildup
- Batch Reactor: Time to Reach a Target Conversion
- Size the Branch Circuit for a 40 hp, 460 V Motor
- Voltage Drop on a 240 V Single-Phase Feeder
- Pump Head, Shaft Power and Motor Size
Questions
Why is steam economy less than 1 here?
Heat is also needed to warm the feed, and real evaporators have heat losses. An economy near 0.8 to 1.0 is typical for a single effect.
How does a multiple-effect evaporator help?
The vapor from one effect heats the next, which runs at a lower pressure. The economy rises roughly in proportion to the number of effects.
Does this size the evaporator?
No. Sizing needs the heat-transfer area, which follows from the duty, the overall heat-transfer coefficient and the temperature difference between the steam and the boiling liquid.