Heat-Pump Performance
SEER2, COP17, COP47, heating capacity and electrical input.
Source guide & equipment file review
Find data sources for your engineering application.
Engineering calculations depend on reliable inputs. Use this page to find equipment performance sources and understand the units, operating conditions and source dates needed to compare values and apply them correctly.
Whether youβre comparing heat-pump efficiency, sizing battery backup or estimating solar production, a traceable source helps you select appropriate inputs and document your assumptions.
Choose an application below, open its available reference and follow the source links. Check that the data matches your equipment and operating conditions before using it in a calculation, simulation or design. Related studios provide tools and learning resources.
Source types: certified and listed ratings, manufacturer performance, measured data, modeled data, and weather/resource data. See the differences β
SEER2, COP17, COP47, heating capacity and electrical input.
Source guide & equipment file review
Discharge curves, temperature effects, aging and cycle life.
5 selected sources & technical references
Efficiency, load, speed and pump performance curves.
5 selected sources & technical references
Irradiance, weather, module ratings and inverter performance.
5 selected sources & technical references
Degradation, failure observations, operating exposure and maintenance history.
5 selected sources & technical references
Weather, building characteristics, measured energy and modeled load profiles.
5 selected sources & technical references
Network parameters, equipment impedances, load profiles and protection references.
5 selected sources & technical references
Understand how each data type is produced and obtained. The organizations below are selected examples across engineering applications, not an exhaustive directory.
Use these to identify equipment and compare ratings under a stated test procedure. Certification programs and equipment lists have different verification scopes.
Search the directory using the complete model number or matched indoor/outdoor combination. Check the certificate or listing, its rating conditions and current status. For AHRI data in a separate tool or website, arrange a signed data license; public lookup is not permission to republish.
Confirm which values the program certifies, the applicable standard and edition, and the exact equipment match. A certified seasonal rating does not make every extended performance point certified.
AHRI data access and licensing βUse model-specific curves and extended tables to evaluate equipment across load, speed and temperature. These may contain tested or engineering-derived values beyond the certified rating points.
Look in the manufacturerβs technical library for engineering submittals, selection data and performance tables. Ask its representative or technical support for the exact model, revision and required operating point. NEEP provides a consolidated heat-pump route, with enhanced downloads available to subscribers.
Preserve model suffixes, configuration, test conditions and the document revision. Confirm whether values are measured or calculated and what power, fan, defrost or auxiliary loads are included. Obtain permission before reproducing tables or distributing derived collections.
NEEP access options βUse laboratory tests to study controlled behavior and field measurements to study installed operation. Keep the two settings identified because installation, duty and environment affect results.
Choose a study and read its methods and data dictionary before downloading. Follow the studyβs raw, processed or hourly file links, or its data-request instructions. Battery Archive requests an email inquiry for complete cell CSV files; some repository entries have access limitations.
Check units, sensor uncertainty, timestamps, sampling intervals, missing data and the measurement boundary. Field COP is not a certified rating. Laboratory aging and accelerated tests do not directly establish a fleet failure rate. Follow study-specific license, privacy and citation requirements.
Example: DOE/NREL cold-climate field study βUse calculated profiles and benchmark systems to test methods, compare scenarios and explore behavior where a complete real-system record is not available.
Select a documented release and scenario, then follow the providerβs dataset or case-download links. Download the model description and assumptions with the files. Choose a format compatible with your analysis software.
Record model version, geography, scenario, aggregation and calibration assumptions. Synthetic grids are not actual utility networks; calibrated load profiles are not raw meter histories. Retain the modeled label and the datasetβs license and required citations.
NASA simulated degradation benchmarks βUse location- and time-specific environmental inputs for energy and equipment studies. Station observations, satellite-derived estimates and typical-year files represent different kinds of evidence.
Select the coordinates or station, variables, period and interval. Use the providerβs search/download interface or documented API; follow any account, key, request-limit and attribution requirements.
Check station location, time zone, daylight-saving treatment, timestamp convention, quality flags and units. A typical meteorological year is not an actual historical year, and a satellite estimate is not an on-site instrument reading.
NSRDB dataset access guide βLooking for a particular equipment value or data source? Contact us β