Column Buckling: Why End Conditions Matter
Compare the Euler buckling load of one slender steel column pinned at both ends and fixed at both ends, and why Euler is not a full column check.
Civil & Structural · Last reviewed
Given
A steel column 5.0 m long with area A = 1,800 mm², minimum-axis second moment of area I = 2.0 × 10⁶ mm⁴, E = 200 GPa and yield stress Fy = 250 MPa. Compare two effective-length assumptions: pinned at both ends (K = 1.0) and fixed at both ends (theoretical K = 0.5).
Find
The ideal Euler buckling load for each assumption, and whether Euler is the controlling check.
Solution
Related tools and labs
Calculators, labs and simulators are part of the All-Access Pass.
More worked problems
- Simply Supported Beam: Reactions, Moment and Deflection
- Cantilever Beam: Tip Load and Deflection
- Footing Bearing Pressure with an Eccentric Load
- Stormwater Runoff Using the Rational Method
- Earthwork Cut and Fill by the Average-End-Area Method
- Size the Branch Circuit for a 40 hp, 460 V Motor
- Voltage Drop on a 240 V Single-Phase Feeder
- Pump Head, Shaft Power and Motor Size
Questions
What does K represent?
The effective-length factor. It shortens or lengthens the real length to the equivalent pinned-pinned length for buckling. A cantilever column (fixed-free) has K = 2.0, so the load is a quarter of the pinned value.
Why does end fixity quadruple the load?
Halving the effective length multiplies the Euler load by four, because the load varies with the inverse square of the effective length.
What do I use for a design check?
The column curves in the governing steel or timber code, which combine Euler buckling and yielding with imperfection effects.
Educational material. Examples use simplified, hypothetical inputs and are not a design, a construction document or professional engineering advice. Confirm requirements with the codes and standards adopted where the work is built and with a licensed engineer.