Start with speed and slip
Synchronous speed is 120 × frequency / poles in rpm. Rotor speed is synchronous speed times one minus the entered slip. Pole count must be a positive even integer within the supported range. Slip is an operating assumption and is not predicted from a motor equivalent circuit.
Carry torque through the transmission
The ratio is motor rpm divided by driven rpm. Driven torque follows the chosen load law, then required motor torque is driven torque divided by ratio and transmission efficiency. Useful mechanical power is torque × 2π × rpm / 60. Transmission losses increase motor shaft demand.
Distinguish load families
Constant torque is an idealized conveyor-type load. Quadratic torque scales with driven-speed squared relative to the entered reference speed, giving an ideal cubic power relationship at the load. Real pumping systems with static head and real fans may depart from that simple law.
Compare operating input rather than nameplate power
Electrical input divides required shaft power by motor and drive efficiencies. Annual energy is that single-point input multiplied by entered hours. There is no start-current model, acceleration inertia, overload duration, motor thermal curve or field-weakening region. Obtain those data before real selection.
Worked example
- At 50 Hz, four poles and 3% slip, motor speed is 1,455 rpm. A 10:1 speed reduction gives 145.5 rpm at the driven load.
- A 400 N·m constant-torque load with 94% gear efficiency requires about 42.553 N·m at the motor, leaving about 7.447 N·m against an entered 50 N·m available torque.
- Useful load power is about 6.095 kW. Shaft input is about 6.484 kW; dividing by 91% motor and 97% drive efficiency gives about 7.345 kW supply input.
Questions and interpretation
Does reducing speed always save cubic power?
No. That relationship describes an ideal quadratic-torque load with fixed efficiencies. Constant-torque loads and systems with static requirements behave differently.
Does torque margin prove the motor will start?
No. Starting and acceleration depend on torque-speed curves, inertia, load breakaway torque and drive limits.
Is available torque always nameplate torque?
No. Frequency, cooling, duty and field weakening can reduce available torque. Enter justified duty data.
Prepare an activity report
Use View / print study report to review a clean summary of your activity, then print it or save a PDF. Download study report (PDF) creates a formatted document with the actual assumptions, results, interpretation and references. Charts and baseline comparisons are included where applicable; security reports summarize recorded runs. Website navigation, purchase panels and unrelated page content are excluded.
References and verification
The linked sources explain the background. The interactive calculations and scenarios are original teaching exercises with explicit assumptions, not certified equipment selection, measured performance or a real security assessment.
Continue the study
Explore the other workbenches
- Electrical Distribution & Protection Workbench
- HVAC System & Energy Workbench
- Pump & Piping System Workbench
- Fire Alarm System Design Workbench
- Structural Beam & Load Path Workbench
- Solar & Battery Microgrid Workbench
- SCADA & Control Loop Workbench
- GPU Memory / VRAM Sizing Calculator
- 800 VDC Power Architecture Explorer
- AI Agent Identity & Security Lab
- Data-Center Water & Energy Comparison
- Inside a Liquid-Cooling System / CDU