Motor & Drive Selection Workbench

A steady-state motor, drive and transmission workbench linking electrical frequency to shaft speed, driven speed, torque and power. It compares a constant-torque load with an ideal quadratic-torque load and keeps motor, drive and gearbox efficiencies separate. The result is a steady operating-point estimate. Available torque must be entered for the actual frequency and cooling condition. It does not guarantee acceleration, starting capability, acceptable harmonics or continuous operation at a low speed.

Published and reviewed · EngineersUniverse · Interactive workspace · All-Access ↓ · Worked example ↓

About this workbench

What it is and its purpose
A steady-state motor, drive and transmission workbench linking electrical frequency to shaft speed, driven speed, torque and power. It compares a constant-torque load with an ideal quadratic-torque load and keeps motor, drive and gearbox efficiencies separate.
Who it is for
For mechanical and electrical learners, maintenance teams and designers developing an initial drive concept. It helps explain the load seen by a motor, not certify a motor/drive pair or replace its torque-speed and thermal documentation.
When and where to use it
Use it when comparing a geared conveyor with a direct-driven fan, changing reduction ratio or explaining how frequency affects a variable-torque load. It is useful before a detailed duty-cycle, starting or acceleration study.
How to use it
Start with the conveyor example. Review frequency, pole count and slip, then expand transmission and load assumptions. Capture a baseline before changing gearing or selecting the fan preset. Read motor torque margin and the separate useful-load, shaft and supply powers.
What the results mean
The result is a steady operating-point estimate. Available torque must be entered for the actual frequency and cooling condition. It does not guarantee acceleration, starting capability, acceptable harmonics or continuous operation at a low speed.
Continue to the interactive workspace ↓

Start with speed and slip

Synchronous speed is 120 × frequency / poles in rpm. Rotor speed is synchronous speed times one minus the entered slip. Pole count must be a positive even integer within the supported range. Slip is an operating assumption and is not predicted from a motor equivalent circuit.

Carry torque through the transmission

The ratio is motor rpm divided by driven rpm. Driven torque follows the chosen load law, then required motor torque is driven torque divided by ratio and transmission efficiency. Useful mechanical power is torque × 2π × rpm / 60. Transmission losses increase motor shaft demand.

Distinguish load families

Constant torque is an idealized conveyor-type load. Quadratic torque scales with driven-speed squared relative to the entered reference speed, giving an ideal cubic power relationship at the load. Real pumping systems with static head and real fans may depart from that simple law.

Compare operating input rather than nameplate power

Electrical input divides required shaft power by motor and drive efficiencies. Annual energy is that single-point input multiplied by entered hours. There is no start-current model, acceleration inertia, overload duration, motor thermal curve or field-weakening region. Obtain those data before real selection.

Worked example

  1. At 50 Hz, four poles and 3% slip, motor speed is 1,455 rpm. A 10:1 speed reduction gives 145.5 rpm at the driven load.
  2. A 400 N·m constant-torque load with 94% gear efficiency requires about 42.553 N·m at the motor, leaving about 7.447 N·m against an entered 50 N·m available torque.
  3. Useful load power is about 6.095 kW. Shaft input is about 6.484 kW; dividing by 91% motor and 97% drive efficiency gives about 7.345 kW supply input.

Questions and interpretation

Does reducing speed always save cubic power?

No. That relationship describes an ideal quadratic-torque load with fixed efficiencies. Constant-torque loads and systems with static requirements behave differently.

Does torque margin prove the motor will start?

No. Starting and acceleration depend on torque-speed curves, inertia, load breakaway torque and drive limits.

Is available torque always nameplate torque?

No. Frequency, cooling, duty and field weakening can reduce available torque. Enter justified duty data.

Prepare an activity report

Use View / print study report to review a clean summary of your activity, then print it or save a PDF. Download study report (PDF) creates a formatted document with the actual assumptions, results, interpretation and references. Charts and baseline comparisons are included where applicable; security reports summarize recorded runs. Website navigation, purchase panels and unrelated page content are excluded.

References and verification

The linked sources explain the background. The interactive calculations and scenarios are original teaching exercises with explicit assumptions, not certified equipment selection, measured performance or a real security assessment.

Continue the study

Explore the other workbenches