A common workflow for different disciplines
The same X/Y extraction workflow can support a single-valued oscilloscope trace, a pump head/flow curve, a stress–strain plot or a thermal response. Choose labels and units appropriate to the source. The 48 built-in examples are explicitly synthetic, not manufacturer curves or real test results.
Calibration and honest precision
The image must be straight and axis-aligned. The selected rectangle corresponds to known minimum and maximum axis values. Linear mapping interpolates values by pixel position; logarithmic mapping interpolates their base-10 logarithms. No OCR, automatic instrument recognition, skew/perspective correction, date/category axes or dual-unit Y axes is claimed. Images are resampled to at most 1,800 pixels on the longer side; enter pixel coordinates in that processing image.
Trace capture and quality checks
Manual capture follows the points you select. Color capture searches each sampled image column inside the rectangle, finds pixels within a selectable RGB distance and takes the median matching row. Columns with no match or widely separated matches are omitted and counted. This is a single Y(X) trace algorithm, unsuitable for XY loops, ambiguous crossings or indistinguishable same-color grid lines. Compare the point overlay with the source before export.
Plain-English reading and domain limits
Every synthetic example has a reading guide, its mathematical model and its limitations. The selected trace also receives a data-based summary of range, maximum location and first-to-last change. Highest does not always mean best: an impedance minimum, return-loss maximum or a zero crossing can have different meanings. These explanations do not diagnose machinery, identify substances, forecast business outcomes or establish protection coordination.
Statistics are not an instrument analysis
Mean and RMS weight each supplied sample equally. Uneven spacing changes their physical interpretation; they are not time-weighted statistics. Peak-to-peak is the observed maximum minus minimum. The signed trapezoidal integral uses sorted X values, is unavailable for repeated X and may bridge gaps. Unit interpretation belongs to the reviewer: a numerical integral is not automatically energy or another physical quantity. FFT, THD, automatic frequency extraction and pass/fail certification are not included.
Local processing and reproducible records
Image and CSV processing occurs in the browser without an analysis-service upload. Website access/analytics are separate; the workspace is marked for session-recording masking. Save study stores bounded numeric data and notes in this browser, not the source image. CSV exports selected trace points; SVG exports the scalable comparison plot; the formatted report includes methods, calibration, summaries, cursor readings, notes and limitations. Closing the page loses unsaved work.
Worked example
- Load the screenshot example. It is a synthetic sine wave, amplitude 5 V and frequency 1 kHz, over a 0–5 ms window. Its processing image is 660 × 350 pixels.
- The known plot rectangle is left 60, right 600, top 40, bottom 300. Axis values are X = 0–5 ms and Y = −6 to +6 V. A pixel at (330,170) therefore maps to (2.5 ms,0 V).
- Extract the yellow curve, inspect omitted/ambiguous column counts and compare the overlaid points. Image-derived extrema are approximate and may differ from ±5 V because the curve has finite thickness and pixel resolution.
- The separate numeric sine example has 501 synthetic points. Its minimum/maximum are −5/+5 V, peak-to-peak is 10 V, sample mean is approximately 0 V and sample RMS is about 3.532 V. Endpoint weighting makes this slightly different from the continuous-cycle 5/√2 = 3.536 V.
Questions and interpretation
Can I upload a phone photo of an oscilloscope?
A photo can be imported, but this version assumes straight, aligned axes. Correct rotation and perspective before use. Manually enter the displayed axis values; the workbench does not identify a scope model or read its settings.
Can I compare several channels?
Up to four traces can share the same numeric X and Y units on one clean plot. Import CSV traces separately, or start another image trace and sample a different color. Separate channels with different units or scales require separate calibrated studies.
Are image points as accurate as the original test data?
No. They approximate pixels in a rendered graph and cannot recover information absent from the image. Prefer original instrument CSV and disclose how points were obtained.
Is this included with All-Access?
Yes. The guide and worked example are public. The interactive digitizer, comparison and exports use your existing All-Access pass.
Prepare an activity report
Use View / print study report to review a clean summary of your activity, then print it or save a PDF. Download study report (PDF) creates a formatted document with the actual assumptions, results, interpretation and references. Charts and baseline comparisons are included where applicable; security reports summarize recorded runs. Website navigation, purchase panels and unrelated page content are excluded.
References and verification
The linked sources explain the background. The interactive calculations and scenarios are original teaching exercises with explicit assumptions, not certified equipment selection, measured performance or a real security assessment.
Continue the study
Explore the other workbenches
- Electrical Distribution & Protection Workbench
- HVAC System & Energy Workbench
- Pump & Piping System Workbench
- Fire Alarm System Design Workbench
- Motor & Drive Selection Workbench
- Structural Beam & Load Path Workbench
- Solar & Battery Microgrid Workbench
- SCADA & Control Loop Workbench
- GPU Memory / VRAM Sizing Calculator
- 800 VDC Power Architecture Explorer
- AI Agent Identity & Security Lab
- Data-Center Water & Energy Comparison
- Inside a Liquid-Cooling System / CDU