Building Energy & Utilities Dashboard

Review building-system interval data alongside a stated reference profile. Calculate kWh from interval-average kW and elapsed hours, filter a system or interval, compare snapshots and explain what the selected records actually support.

Published and reviewed · EngineersUniverse · Interactive workspace · All-Access ↓ · Worked example ↓

About this workbench

What it is and its purpose
Review building-system interval data alongside a stated reference profile. Calculate kWh from interval-average kW and elapsed hours, filter a system or interval, compare snapshots and explain what the selected records actually support.
Who it is for
For engineering students, engineers, operations teams and professionals learning to review operational data and system handoffs.
When and where to use it
Use example scenarios for learning or compatible local data for a bounded exploratory study. This is not a live monitoring or enterprise integration service.
How to use it
Read the worked example, open the workspace with All-Access and change one input or workflow action at a time. Inspect underlying records, capture comparisons where offered, and download a report with assumptions and findings.
What the results mean
Results describe the supplied records or the recorded simulation. They do not establish compliance, predict failures, authorize actual work, send messages or connect to external equipment.
Continue to the interactive workspace ↓

Integrate interval power with explicit hours

Interval energy = average kW × interval hours. Sum only the provided nonoverlapping records. Imports require timezone-qualified ISO timestamps; gaps are not filled and there is no annualization or assumed continuous coverage.

Keep reference and cost assumptions separate

The reference is the baselineKw value in each matching interval, not a weather-normalized model. Actual-reference difference is not automatically a verified saving. Cost = selected kWh × entered USD/kWh; demand charges, taxes and fixed fees are excluded.

Use temperatures and peaks with the right boundary

Temperature is contextual source data. The highest average-demand record belongs to one system/interval and is not a simultaneous building billing peak. This version does not calculate calibrated comfort compliance, EUI ratings or an ENERGY STAR score.

Compare matching coverage

A difference is meaningful only for the same systems and time coverage. The chart groups energy by recorded interval start; unlike a billing-demand calculation, it does not reconstruct coincident building demand or infer missing measurements.

Worked example

  1. The example contains six 1 h intervals for HVAC and lighting. HVAC uses 270 kWh and lighting 60 kWh: total 330 kWh.
  2. The stated reference is 312 kWh, so the difference is 18 kWh, or 5.769% above reference.
  3. At 0.15 USD/kWh the energy-only cost is 49.50 USD. The highest single-system interval average is 50 kW; do not interpret it as the whole-building demand peak.

Questions and interpretation

Can I use my own data?

The three dashboards and integration lab accept bounded CSV/JSON data matching their downloadable templates. The production and portal demos use explicit local scenario controls; all six can export their activity or dataset. No analysis-service upload is used.

Does this connect to my company systems?

No. These are original local tools and teaching simulations. Existing website access and analytics still apply. Real PLC, ERP, MES or customer-account connections would be a separate implementation.

What is saved?

Working state is session-local. Download CSV/JSON or a formatted report before leaving. No automatic cross-device or cloud synchronization is included.

Prepare an activity report

Use View / print study report to review a clean summary of your activity, then print it or save a PDF. Download study report (PDF) creates a formatted document with the actual assumptions, results, interpretation and references. Charts and baseline comparisons are included where applicable; security reports summarize recorded runs. Website navigation, purchase panels and unrelated page content are excluded.

References and verification

The linked sources explain the background. The interactive calculations and scenarios are original teaching exercises with explicit assumptions, not certified equipment selection, measured performance or a real security assessment.

Continue the study

Explore the other workbenches