Integrate interval power with explicit hours
Interval energy = average kW × interval hours. Sum only the provided nonoverlapping records. Imports require timezone-qualified ISO timestamps; gaps are not filled and there is no annualization or assumed continuous coverage.
Keep reference and cost assumptions separate
The reference is the baselineKw value in each matching interval, not a weather-normalized model. Actual-reference difference is not automatically a verified saving. Cost = selected kWh × entered USD/kWh; demand charges, taxes and fixed fees are excluded.
Use temperatures and peaks with the right boundary
Temperature is contextual source data. The highest average-demand record belongs to one system/interval and is not a simultaneous building billing peak. This version does not calculate calibrated comfort compliance, EUI ratings or an ENERGY STAR score.
Compare matching coverage
A difference is meaningful only for the same systems and time coverage. The chart groups energy by recorded interval start; unlike a billing-demand calculation, it does not reconstruct coincident building demand or infer missing measurements.
Worked example
- The example contains six 1 h intervals for HVAC and lighting. HVAC uses 270 kWh and lighting 60 kWh: total 330 kWh.
- The stated reference is 312 kWh, so the difference is 18 kWh, or 5.769% above reference.
- At 0.15 USD/kWh the energy-only cost is 49.50 USD. The highest single-system interval average is 50 kW; do not interpret it as the whole-building demand peak.
Questions and interpretation
Can I use my own data?
The three dashboards and integration lab accept bounded CSV/JSON data matching their downloadable templates. The production and portal demos use explicit local scenario controls; all six can export their activity or dataset. No analysis-service upload is used.
Does this connect to my company systems?
No. These are original local tools and teaching simulations. Existing website access and analytics still apply. Real PLC, ERP, MES or customer-account connections would be a separate implementation.
What is saved?
Working state is session-local. Download CSV/JSON or a formatted report before leaving. No automatic cross-device or cloud synchronization is included.
Prepare an activity report
Use View / print study report to review a clean summary of your activity, then print it or save a PDF. Download study report (PDF) creates a formatted document with the actual assumptions, results, interpretation and references. Charts and baseline comparisons are included where applicable; security reports summarize recorded runs. Website navigation, purchase panels and unrelated page content are excluded.
References and verification
The linked sources explain the background. The interactive calculations and scenarios are original teaching exercises with explicit assumptions, not certified equipment selection, measured performance or a real security assessment.
Continue the study
Explore the other workbenches
- Industrial Operations Dashboard
- Asset & Maintenance Dashboard
- ERP-to-MES Production Workflow Lab
- Systems Integration & Data Mapping Lab
- Client Service Portal Workflow Demo
- Graph Digitizer & Test Report Workbench
- Electrical Distribution & Protection Workbench
- HVAC System & Energy Workbench
- Pump & Piping System Workbench
- Fire Alarm System Design Workbench
- Motor & Drive Selection Workbench
- Structural Beam & Load Path Workbench
- Solar & Battery Microgrid Workbench
- SCADA & Control Loop Workbench
- GPU Memory / VRAM Sizing Calculator
- 800 VDC Power Architecture Explorer
- AI Agent Identity & Security Lab
- Data-Center Water & Energy Comparison
- Inside a Liquid-Cooling System / CDU